AC SPD – 100kA per phase surge protection devices  NKP-DY-I-100-4P z
AC SPD – 100kA per phase surge protection devices  NKP-DY-I-100-3P zAC SPD – 100kA per phase surge protection devices  NKP-DY-I-100-3P yAC SPD – 100kA per phase surge protection devices  NKP-DY-I-100-4P yAC SPD – 100kA per phase surge protection devices  NKP-DY-I-100-4P z

Pluggable AC Surge Protection Devices 100kA per phase 8/20µs NKP-DY-I-100

80,000 amp per phase surge suppressor (SPD) for AC power distribution system

  • Imax – 80kA/Phase (8/20μs waveform)
  • Uc – 385V for main distribution panel
  • Up –low protection level 2.1kV/phase
  • Short action response time, only 25ns
  • Advanced anti-surge components MOV/Gas Spark
  • State-of-the-art surge protection technology
  • Failure status indicator, green/red
  • Simple installation, easy maintenance

 

Compare
编码: piece 分类: 标签: , , , ,

产品描述

 

NKP-DY-I-100(8/20µs)

NKP-100 series SPDs are designed to protect electric and sensitive equipments against induced surge. This surge protective device spots its capacity to withstand impulse current with 8/20µs wave form and low voltage protection level. This SPDs are installed in the main distribution panel of this installation.

 

Main Features

  • Imax - 100kA/Phase (8/20μs waveform)
  • Uc - 385V for main distribution panel
  • Up –low protection level 2.3kV/phase
  • Short action response time, only 25ns
  • Advanced anti-surge components MOV/Gas Spark
  • State-of-the-art surge protection technology
  • Failure status indicator, green/red
  • Simple installation, easy maintenance

 

Product Parameter

Model No.NKP-I-100
ELECTRICAL CHARACTERISTICS
Power System220/380V main distribution panel
Protection ModeTT-TN-IT
Nominal Discharge Current (In)[8/20us]60kA(8/20µs)
Maximal Discharge Current (Imax)[8/20us]100kA(8/20µs)
Nominal Voltage(Un)AC 220V
Maximal Continuous Operating a.c. Voltage(Uc)AC 385V
Voltage Protection Level at In (Up)<2.3kV
Response Time (tA)25ns
Status Indicator/
Telesignalisation Remote Indicator(TS)/
Maximal Back-up Fuse63A gG
Follow Currentnone
MECHANICAL CHARACTERISTICS
Connection Cross-section (min.)10mm2 stranded
Connection Cross-section (max.)50mm2 stranded
Place of Installationindoor
Mounting35mm2 DIN rails acc. to EN 60715
Enclosure Materialthermoplastic acc. to UL94 V-0
Enclosure Color grey
Degree of ProtectionIP20
Test StandardGB 18802.1-2011 / IEC 61643-1
ENVIRONMENTAL CHARACTERISTICS
Stocking Temperature -40℃~+80℃ (-104℉-176℉)
Operating Temperature-40℃~+80℃ (-104℉-176℉)
Relative Humidity (RH)5% - 95% (non-condensing)
Operating Altitude<3000m (9843ft)
Dimension(L*W*H)143mm*66mm*93mm
Weight(G/W)

 

 

Electrical Diagram

NKP-100 electrical

 

Wiring Diagram

Class I SPD wiring

 

Wiring (TT-TN-IT) NKP-100

 

Dimension

nkp-i-100  size

 

 *Installation Notes

1. For best performance, mount protector as close t service panel as possible, protector must be connected to a dedicated overcurrent devices sized for the protector's wires.

2. Must install SPD strictly according to the wiring diagram provided

“L1, L2, L3” – live line

“N” – null line

“PE” – Earth wire/Grounding line.

3. Must cut off the power before installation, no hot-line operation is allowed, and better to under the guidance of professional electrician.

4. Green tab, normal work status, Red tab, failure status, need to be replaced Rapidly. 5. Grounding wire should be as thick and short as possible, resistance<10Ω. The grounding line: BVR≥2.5 mm2.

 

00 Model Selection Table

Model Configuration
NKP-100/385/2PAC SPD, 100kA/Phase, 8/20µs, for single-phase 2-line/3-line AC main power distribution system, 35mm DIN Rail
NKP-100/385/3PAC SPD, 100kA/Phase, 8/20µs, for TN-C three-phase 4-line AC main power distribution system, 35mm DIN Rail
NKP-100/385/4PAC SPD, 100kA/Phase, 8/20µs, for TN-S three-phase 5-line AC main power distribution system, 35mm DIN Rail

 

用户评论

目前还末有评论

我要第一个评论! “Pluggable AC Surge Protection Devices 100kA per phase 8/20µs NKP-DY-I-100”