Type 2 Solar PV Surge Protection Devices 40kA per pole 8/20μs DC1000V KDY-40R-D1000

40,000 amp, DC1000V PV surge arrester(SPD) for solar panel photovoltaic power system

  • Type 2 surge protector for photovoltaic system
  • Imax – 40kA/pole (8/20 waveform)
  • Un – 1000V DC
  • Up -3.8kV @ In
  • Fast clamp response, under 25ns
  • No leakage, no operating currents
  • High energy anti-surge components MOV
  • State-of-the-art surge protection technology
  • Failure status indicator, green/red
  • Telesignailsation indicator for remote failure alerts
  • DIN rail mounting, pluggable module, convenient replacement
Compare
编码: piece 分类: 标签: , , , ,

产品描述


 

KDY-40R-D1000/3P(8/20µs)

KDY-40R-D1000 series type 2 solar PV surge arresters/SPD is designed to protect DC powered equipments against lightning surge voltages in photovoltaic power supply network, such as inverters, combiner boxes and charge controllers. It utilizes high energy metal oxide varistors/MOV, providing a protection in CM/DM(L-PE, N-PE, L-N).

 

Main Features

  • Type 2 surge protector for photovoltaic system
  • Imax - 40kA/pole (8/20 waveform)
  • Un - 1000V DC
  • Up -3.8kV @ In
  • Fast clamp response, under 25ns
  • No leakage, no operating currents
  • High energy anti-surge components MOV
  • State-of-the-art surge protection technology
  • Failure status indicator, green/red
  • Telesignailsation indicator for remote failure alerts
  • DIN rail mounting, pluggable module, convenient replacement

 

Product Parameter

Model No.KDY-40R-D1000/3P
ELECTRICAL CHARACTERISTICS
NetworkPV network 1000V DC
Protection ModeCM/DM
Nominal PV Operating Voltage(Un)1000V DC
Maximal PV Operating Voltage(Uc)1200V DC
Nominal Discharge Current (In)[8/20us]20kA(8/20µs)
Maximal Discharge Current (Imax)[8/20us] 40kA(8/20µs)
Voltage Protection Level at In (Up)<3.8kV
Response Time (tA)25ns
Status IndicatorGreen/Red tabs
Telesignalisation Remote Indicator(TS)1NO+1NC
Maximal Back-up Fuse25-40A gG
Follow Currentnone
MECHANICAL CHARACTERISTICS
Connection Cross-section (min.)4mm2 solid
Connection Cross-section (max.)25mm2 stranded
Connection to Networkterminals
Place of Installationindoor
Mounting35mm2 DIN rails acc. to EN 60715
Enclosure Materialthermoplastic acc. to UL94 V-0
Enclosure Color white
Degree of ProtectionIP20
Test StandardGB 18802.1-2011 / IEC 61643-1
ENVIRONMENTAL CHARACTERISTICS
Stocking Temperature -40℃~+80℃ (-104℉-176℉)
Operating Temperature-40℃~+80℃ (-104℉-176℉)
Relative Humidity (RH)5% - 95% (non-condensing)
Operating Altitude<3000m (9843ft)
Dimension(L*W*H)36mm*63mm*91mm
Weight(G/W)

 

 

Electrical Diagram

...............

 

Wiring Diagram

................

 

Dimension

................

 

 *Installation Notes

  1. Installation must be performed only by electrically skilled operator.
  2. Disconnect power before installing, no hot-line operation is allowed, and better to under the guidance of professional electrician.
  3. For best performance, mount protector in parallel with the equipment it is protecting as close as possible. (*Note: If protector is to be located outdoors and exposed to elements, mount protector inside a suitable weatherproof enclosure.)
  4. Use a circuit breaker in series with the protector.(*Note: if a breaker is not available, use a fused disconnect switch or a fuse block. Fuses should be time-delay type.)
  5. Green tab, normal work status, Red tab, failure status, need to be replaced rapidly.

 

00 Model Selection Table

Model Configuration
KDY-20-D600/2Ppluggable solar PV SPD, 20kA/pole, 8/20µs, for DC600V solar photovoltaic power system, 35mm DIN Rail
KDY-40-D600/2Ppluggable solar PV SPD, 40kA/pole, 8/20µs, for DC600V solar photovoltaic power system, 35mm DIN Rail
KDY-20-D900/2Ppluggable solar PV SPD, 20kA/pole, 8/20µs, for DC900V solar photovoltaic power system, 35mm DIN Rail
KDY-40-D900/2Ppluggable solar PV SPD, 40kA/pole, 8/20µs, for DC900V solar photovoltaic power system, 35mm DIN Rail
KDY-40R-D1000/3Ppluggable solar PV SPD, 40kA/pole, 8/20µs, remote signaling for failure alerts, for DC1000V solar photovoltaic power system, 35mm DIN Rail

用户评论

目前还末有评论

我要第一个评论! “Type 2 Solar PV Surge Protection Devices 40kA per pole 8/20μs DC1000V KDY-40R-D1000”