产品描述
NKP-TEL-4C-2a/2a1
The NKP-TEL-4C-2a/2a1 surge protector is designed to protect coaxial signal equipment against transients caused by lightning, electrostatic discharge and ground surges that can enter equipment from the signal lines. The NKP-TEL-4C-2a/2a1 features BNC connectors for camera, cable TV, cable network, and satellite antenna and features terminal blocks for power. The systematic use of MOV, gas discharge tube and fast clamping diodes, provides a large discharge current capacity and low attenuation, ensuring reliable communication.
Main Features
- Coaxial signal surge protector
- Camera/cable network/satellite antenna
- Combined coaxial surge protection for power and video
- BNC9 connector/terminal blocks
- Ultrafast response time <1ns
- Transmission Rate: 20MHz
- Systematic use of MOV, 3-pole gas tube and fast clamping diode
Product Parameter
Model No. | NKP-TEL-4C-2a/2a1 |
---|---|
ELECTRICAL CHARACTERISTICS | |
Typical Application | combined coaxial video and power system |
Nominal Operation Voltage(Un) | Video: ≤6Vdc; Power: 15-220V dc/ac |
Maximal Operation Voltage (Uc) | Video: 8Vdc; Power: 270V dc/ac |
Nominal Discharge Current (In) | Video(C2): 5kA (8/20μs); Power(T2): 3kA (8/20μs) |
Maximal Discharge Current (Imax) | Power(T2): 6kA (8/20μs) |
Voltage Protection Level (Up) | Video(C2): ≤500V; Power(T2): ≤1800V |
Response Time (tA) | 1ns |
Insertion Loss | ≤0.5dB (20MHz) |
Max. Transmission Rate | 20Mbps |
MECHANICAL CHARACTERISTICS | |
I/O Connector | Video: BNC9/BNC9; Power: terminal blocks |
Protection Port Numbers | each line protection for power/video |
Failure Indicator | / |
Place of Installation | indoor |
Mounting | 35mm standard rail (optional) |
Enclosure Material | aluminum alloy |
Enclosure Color | silver |
Degree of Protection | IP20 |
Test Standard | GB/T18802.21/IEC61643-21 |
ENVIRONMENTAL CHARACTERISTICS | |
Stocking Temperature | -5℃~+40℃ (-41℉-104℉) |
Operating Temperature | -20℃~+70℃(-68℉-158℉) |
Relative Humidity (RH) | 5% - 95% (non-condensing) |
Operating Altitude | <3000m (9843ft) |
Dimension(L*W*H) | 4C-2a:103mm*38mm*76mm; 4C-2a1:86mm*40mm*52mm |
Weight(G/W) |
Electrical Diagram
Wiring Diagram
NKP-TEL-4C-2a
NKP-TEL-4C-2a1
Dimension
NKP-TEL-4C-2a
NKP-TEL-4C-2a1
*Installation Notes
- Must disconnect power before installation, no hot-line operation is allowed, and better to under the guidance of professional electrician.
- For best performance, mount protector in serial with the equipment it is protecting as close as possible, and better to install one protector at each end of the data line.
- The ground wire on the product (if included) must be attached directly to the metal chassis of the equipment to be protected. The length of the grounded wire is not to exceed 11 inches.
- No special maintenance is needed, however regular inspection is needed, especially during storm seasons.
Model Selection Table
Model | Configuration |
---|---|
NKP-TEL-4C | Coaxial Surge Protection Devices for Video Surveillance, BNC-K/BNC-J Connector |
NKP-TEL-4U | Coaxial Surge Protection Devices for Video Surveillance, 8/16 ports, BNC-K/BNC-K Connector, 19” inches rack-mount |
NKP-TEL-4C-T | Coaxial Surge Protection Devices for Satellite antenna and Cable network, specific connectors for all appliances(N, BNC, F, L16, SL16, etc.) |
用户评论